OrcaSlicer Calibration Guide: Every Test, in the Right Order
OrcaSlicer calibration works best in a specific order, and in OrcaSlicer 2.5 the Calibration menu shows it: the first five items, top to bottom, are the sequence. This orca slicer calibration guide covers every step in that order, with a guide, a free calculator and a video for each.
Checked against OrcaSlicer 2.5.1 (November 2026).
The order at a glance
Section titled “The order at a glance”| Stage | Step | Guide + calculator |
|---|---|---|
| 0 · Printer (once per machine) | Extruder rotation distance | Rotation Distance |
| Z offset and probe X/Y offsets | X and Y Offsets | |
| Belt tension | Belt Tension | |
| Input shaping (with accelerometer) | Input Shaping | |
| 1 · Every filament | 1. Temperature | Temperature Tower |
| 2. Max volumetric speed | Max Volumetric Speed | |
| 3. Pressure advance | Pressure Advance | |
| 4. Flow ratio | Flow Rate | |
| 5. Retraction | Retraction Tuning | |
| 2 · Advanced (optional) | Cornering, input shaping, VFA | — |
| Adaptive pressure advance | Adaptive PA | |
| Extrusion rate smoothing | ERS | |
| 3 · Last | Tolerance | — |
| Skew correction | Skew Correction |
Stage 1 is OrcaSlicer’s own recommended filament order. Stage 0 is mine: the Calibration menu assumes your printer is already mechanically right.
Why the order matters
Section titled “Why the order matters”Each test assumes the ones before it are already correct. Change an earlier setting and the later results shift.
- Temperature changes how the plastic melts, which changes how fast you can push it and how it responds to pressure.
- Max volumetric speed sets the ceiling. Pressure advance or flow tested above it is measuring a hotend that can’t keep up.
- Pressure advance and flow ratio can swap. OrcaSlicer’s guide allows either order. If your flow ratio changes a lot, run a quick pressure advance test again.
- Retraction comes last of the five, because stringing changes with everything above it.
OrcaSlicer’s menu used to be in a different order, and older guides followed it. If you learned to start with flow, that’s why.
Stage 0 — The printer
Section titled “Stage 0 — The printer”Do these once per machine, before any filament test. None of them are in the Calibration menu.
Extruder rotation distance
Section titled “Extruder rotation distance”If the extruder doesn’t move the length of filament it’s told to, flow ratio will cover the error for one filament and then break when you change spools. Flow ratio is per filament; rotation distance is per printer. Fix it at the printer. → Guide · Calculator
Z offset and probe offsets
Section titled “Z offset and probe offsets”Z offset sets your first layer height. Get it wrong and every test print after it is off. The probe’s X/Y offsets make sure the bed mesh is measured where the nozzle actually prints. → Guide · X/Y Offsets Calculator
Belt tension
Section titled “Belt tension”Loose or uneven belts show up as ringing and dimensional error that no slicer setting will fix. → Guide · Calculator
Input shaping, if you have an accelerometer
Section titled “Input shaping, if you have an accelerometer”On Klipper with an accelerometer (the K2 Plus and SV08 have one built in), run SHAPER_CALIBRATE here. It measures the printer, not the filament, and needs no calculator. No accelerometer? Do input shaping in Stage 2 instead. → Guide
Stage 1 — Every filament
Section titled “Stage 1 — Every filament”These are the first five items in Calibration, top to bottom. Repeat them for each new filament, not once per material family.
1. Temperature
Section titled “1. Temperature”Calibration → Temperature. Prints a tower with a different temperature in each band. Judge layer adhesion first, then stringing, bridging and surface. → Guide · Calculator · Video
2. Max volumetric speed
Section titled “2. Max volumetric speed”Calibration → Max flowrate. Finds how much plastic per second your hotend can melt with this filament before quality fails. Set a value just below the failure point, not at it. → Guide · Calculator · Video
3. Pressure advance
Section titled “3. Pressure advance”Calibration → Pressure advance. Choose the tower, line or pattern test. You’re looking for sharp corners with no bulge and no gap. → Guide · Calculator · Video · All three tests compared
4. Flow ratio
Section titled “4. Flow ratio”Calibration → Flow ratio. Pick the patch with the smoothest top surface, then apply the modifier to your current flow ratio. → Guide · Calculator · Video
5. Retraction
Section titled “5. Retraction”Calibration → Retraction. Find the shortest retraction that clears stringing. → Guide · Calculator · Video
Stage 2 — Advanced (optional)
Section titled “Stage 2 — Advanced (optional)”Do these once Stage 1 is dialed in, and mainly if you print fast.
- Cornering: Calibration → Cornering. Tunes jerk or junction deviation.
- Input Shaping: Calibration → Input Shaping, two steps: Input Shaping Frequency first, then Input Shaping Damping/zeta factor. Skip it if you used an accelerometer in Stage 0. On Klipper, the ringing tower method is the other no-accelerometer route → Guide · Calculator
- VFA: Calibration → VFA. Finds the speeds that cause vertical fine artifacts on walls, so you can avoid them.
- Adaptive pressure advance: pressure advance values that change with speed and acceleration. There’s no separate menu item: open Calibration → Pressure advance again and enter several print speeds and accelerations, separated by commas. Choose its test speeds from your input shaping results, which is another reason shaping comes first. → Guide · Calculator · Video
- Extrusion rate smoothing: not on OrcaSlicer’s list, but it belongs after pressure advance. Setting it earlier hides the thing pressure advance is trying to measure. → Guide · Calculator
Stage 3 — Last
Section titled “Stage 3 — Last”Tolerance
Section titled “Tolerance”The tolerance test is no longer in the Calibration menu. In Prepare, right-click the plate → Add Handy Model → Orca Tolerance Test. OrcaSlicer’s guide puts it last. Temperature and flow ratio both change your dimensions, so test tolerance after they’re set.
Skew correction
Section titled “Skew correction”If square parts measure out of square, correct it here. → Guide · Calculator
When you’re done: leave calibration mode
Section titled “When you’re done: leave calibration mode”Go to File → New Project once you’ve finished calibrating. That exits calibration mode, so test settings don’t carry into your next print.
Common mistakes
Section titled “Common mistakes”- Tuning flow before rotation distance. The error moves into the wrong setting.
- Running pressure advance or flow tests faster than your max volumetric speed. You end up measuring the hotend’s limit, not the setting.
- Calibrating “PLA” once. Silk, matte and carbon-filled PLA behave differently. Calibrate each filament.
- Skipping the new project at the end. Calibration settings carry into your next print.
